From computer tomograph PSU, I removed battery of capacitors. It is 12 high power electrolytic capacitors. 6 x 12000μF and 6 x 8200μF. All caps working ant 400V (450V surge). Total 121200μF (0,12F). We can charge them to about 400V and store about 9696J of energy. Lots of energy. And lots of lethal energy. It can kill you.
More about capacitor calculations in older blog entry.